Dimensions and Installation Information (in inches)
GTDL740ED
GE
®
7.8 cu. ft. capacity long-venting electric dryer
Specification Revised 3/14
370171
Exhaust Options:
3-way via rear, right and bottom.
NEMA Receptacle codes:
3-prong dryer cord/30A/4' long (cat #WX9X2) is for
NEMA10-30R receptacle
4-prong dryer cord/30A/4' long (cat #WX9X18) is for
NEMA14-30R receptacle
Circuit Requirements:
An individual, properly-grounded branch circuit, protected
by a 30-amp circuit breaker or a time-delay fuse, is
required.
Electric Dryer Rating:
240V, 5000W, 25A, 60Hz
208V, 4784W, 23A, 60Hz
Note: Dryer wall outlet must be located within 36" of
service cord entry and accessible when dryer is mounted
in position.
Installation Information: For complete information, see
installation instructions packed with your dryer.
Special Installation Requirements
Alcove or Closet Installation:
If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side
3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of
open area equally distributed. If this closet contains both a washer and a dryer, doors must contain
a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence of local codes, with the National
Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
Minimum clearances to combustible surfaces
0" both sides
3" rear
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - GTDL740ED

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.6

Page 2

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.6

Page 3

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.6

Page 4

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.6

Commentaires sur ces manuels

Pas de commentaire