GTDS850/855ED
GE
®
7.8 cu. ft. capacity electric dryer with stainless steel drum and steam
Specification Revised 3/14
370177
Electric Dryer Rating:
240V
5000W 25A 60Hz
208V
4784W 23A 60Hz
Exhaust Option: 4-way rear, right, left and bottom
Circuit Requirements: An individual, properly-grounded
branch circuit, protected by a 30-amp circuit breaker or a
time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36" of service
cord entry and acessible when dryer is mounted in position.
Installation Information: For complete information, see
installation instructions packed with your dryer.
Dimensions and Installation Information (in inches)
Special Installation Requirements
Alcove or Closet Installation:
If your dryer is approved for installation in an alcove or closet, it will be stated on a label
on the dryer back.
• The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
Closet doors must be louvered or otherwise ventilated and must contain a minimum
of 60 sq. in. of open area equally distributed. If this closet contains both a washer and
a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence of local codes,
with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryer Exhausting Information : Use metal duct only, vertical and horizontal ducting.
Power Cord Locations 7.8 cu. ft. dryers
Vue de la page 0
1 2 3

Résumé du contenu

Page 1 - GTDS850/855ED

Listed by Underwriters LaboratoriesFor answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or ca

Page 2

For complete information, see installation instructions packed with your dryer.Ducting Materials: For best performance, this dryer should be vented wi

Page 3

Features and Benefits• Steam Select - For the best results, customize your cycle by specifying the number of garments needing to be steamed• Steam

Modèles reliés GTDS850EDWS

Commentaires sur ces manuels

Pas de commentaire