Straight Stanchion Cover (See Figure 6)
Attach mounting arm onto conduit. Hang ballast housing
on cover by hinge. Proceed to Wiring.
35-201578-T8 (1/00 GELS)
IF MULTIWATT:
Multiwatt ballasts are available in various combina-
tions of wattage. See wiring instructions on wiring
tag inside the luminaire.
BALLAST HOUSING INSTALLATION
Swing unit shut. Tighten ballast cover screw securely.
LAMP INSTALLATION
Angle Stanchion Cover (See Figure 7)
Attach mounting arm onto conduit. Hang ballast housing
on cover by hinge. Proceed to Wiring.
B.WIRING:
Cut incoming supply conductors to six (6)
inches inside cover. Route conductors through lead
clip provided and make electrical connections,
including ground as shown on wiring label (See
Figure 8).
CAUTION
Risk of burn
Allow lamp/fixture to cool before
handling
Make all electrical connections in accordance with
the National Electrical Code and any applicable local
code requirements.
Verify that supply voltage is correct by comparing it
to nameplate.
When changing voltage on reconnectable units,
move only the lead with the insulated connector.
IF SINGLE VOLTAGE:
All single voltage ballasts are pre-wired such that
user need only connect the supply conductors.
IF MULTIVOLT: (120/208/240/277 volts)
Connect the ballast lead with the insulated terminal
to the desired voltage terminal as indicated on the
ballast terminal nameplate.
Figure 5
Figure 6
Figure 7
Figure 8
Use only lamps specified on nameplate. Observe
lamp manufacturer’s recommendations and restric-
tions on lamp operation, particularly ballast type,
burning position, etc.
Lamp Tightness – Medium Base Lamp: The lamp should be
tightened to a light firmness sufficient to depress the center
contact.
OPTICALS
CAUTION: GLOBE IS TEMPERED GLASS. DO NOT
SCRATCH OR CHIP.
Attach globe by threading firmly into bottom of ballast
housing.
Prismatic Refractor Assembly
Type V, R or L
Thread adapter firmly into ballast housing. To orient
asymmetrical glass, loosen clamping screws, turn glass and
retighten screws. To relamp, unscrew complete optical from
ballast housing.
ACCESSORIES
External Reflector
Insert mounting screws. Orient reflector to proper position
and slip over mounting screws. Turn reflector and tighten
screws securely.
Globe Guard
Insert protective guard into ballast housing and turn until
retained by detent.
MAINTENANCE AND CLEANING
It will occasionally be necessary to clean optical assembly
in order to maintain light levels. Frequency of cleaning will
depend on dirt levels in user’s facility and minimum accept-
able light levels . Reflector should be cleaned with any
suitable, non-abrasive solution of water and soap or deter-
gent. Residual cleaning agent should be removed with clean
water rinsing. Glassware may be cleaned with any conven-
tional glass cleaner. If unit gets soiled on the inside, it should
be cleaned and any damaged gasket or filter replaced.
MOUNTING ARM
COVER
MOUNTING
SCREWS
CUSTOMER LEADS
WIRING
BOX
TETHER
BALLAST HOUSING
CUSTOMER LEADS
BALLAST
HOUSING
COVER
WIRING BOX DOOR
CUSTOMER LEADS
BALLAST HOUSING
COVER
MOUNTING ARM
SET SCREW
LEAD CLIPS
GEH-5754A
Mini•Gard Luminaire
INSTRUCTIONS
®Registered Trademark of General Electric Company
THE OPERATING TEMPERATURE “T-CODE” LISTED
FOR THIS LUMINAIRE IS BASED ON THE FOLLOWING
BULB SIZES. USE OF OTHER THAN THESE MAY
RESULT IN A HIGHER OPERATING TEMPERATURE
AND COULD RESULT IN A HAZARDOUS CONDITION.
LAMP TYPE WATTAGE BULB SIZE
HIGH PRESSURE SODIUM 70,100,150 ED 23 1/2
HIGH PRESSURE SODIUM 250, 400 ED 18
METAL HALIDE/MERCURY 175, 250 ED 28
METAL HALIDE/MERCURY 400 ED 37
AVERTISSEMENT: COUPER L’ALIMENTATION
AVANT L’INSTALLTION OU L’ENTRETIEN.
GENERAL
A complete luminaire consists of a ballast housing,
optical assembly, and a cover/mounting.
CAUTION: When installing luminaire in
hazardous locations check operating temperature
limits prior to installation to insure it conforms to
the environmental temperature restrictions and
NEC classifications.
MOUNTING INSTALLATION
Flexible Cover (See Figures 2 and 3)
Loosen four(4) bolts holding mounting hub to cover.
Position adapter plate correctly to balance luminaire. Use
widest bolt spacing possible to secure plate to cover. Hang
ballast housing on cover by hinge. Proceed to Wiring.
WARNING
Risk of electric shock
Turn power off before servicing
see instructions
Ceiling Cover (See Figure 4)
Using the slotted tabs, mount cover to ceiling. Hang
ballast housing on cover by hinge. Proceed to Wiring.
Figure 2 Figure 3
Figure 4
CAUTION
Unit will fall if not installed properly
Follow installation instructions
Pendant Cover (See Figure 1)
Thread cover onto conduit. Orient cover and seal around
conduit using approved NEC procedures. Tighten set screw
at mounting hub. Hang ballast housing on cover by hinge.
Proceed to Wiring.
READ THOROUGHLY BEFORE INSTALLING
Figure 1
BALLAST HOUSING
CUSTOMER LEADS
COVER
.875
ADJUSTMENT
CUSTOMER LEADS
BALLAST HOUSING
MOUNTING HUB
COVER
Bolt pattern
for lower
wattages
Bolt pattern
for higher
wattages
GROUND
SCREW
BALLAST HOUSING
CUSTOMER LEADS
COVER
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in
connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which
are not covered sufficiently for the purchaser's purposes, the matter should be referred to General Electric Company.
Wallmount Cover (See Figure 5)
Mount wiring box provided and pull leads. Tether is
supplied to hold arm assembly while connecting supply
leads. Attach arm assembly to wiring box. Do not damage
gasket attached to arm assembly. Mounting screws should
be tightened in alternate sequence. Hang ballast housing
on cover by hinge. Proceed to Wiring.
g
GE Consumer & Industrial
Lighting Systems
East Flat Rock, NC 28726
GE Consumer & Industrial
Lighting Systems
3010 Spartanburg Highway
East Flat Rock, NC 28726
(828) 693-2000
www.gelightingsystems.com
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Mini•Gard Luminaire

Straight Stanchion Cover (See Figure 6)Attach mounting arm onto conduit. Hang ballast housingon cover by hinge. Proceed to Wiring.35-201578-T8 (1/00 G

Page 2

Straight Stanchion Cover (See Figure 6)Attach mounting arm onto conduit. Hang ballast housingon cover by hinge. Proceed to Wiring.35-201578-T8 (1/00 G

Commentaires sur ces manuels

Pas de commentaire