GE PSFA Fiche technique Page 1

Naviguer en ligne ou télécharger Fiche technique pour Lumières des projecteurs GE PSFA. GE PSFA Data Sheet Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Lighting Systems

imagination at worksports lightingparks and recreational facilitiesGE IndustrialLighting Systems

Page 2 - Complete Lighting

Warm Up & Restrike TimeHID lamps require 3-7 minutes to warm up and willnot restrike immediately if there is momentary powerinterruption. Some for

Page 3

Sports LightingSystem SelectionFACILITYCLASSI IIIIIIVProfessionalXCollegeXXSemi-ProfessionalXXSport ClubsXXXAmateur LeaguesXXXHigh SchoolsXXXTraining

Page 4

Typical LayoutsPole LocationBaseball lighting is divided into the infield and outfield portions of the field. The infield lighting is supplied bylumin

Page 5

Sports LightingBaseballStandard 1500 Watt Metal Halide (PSFA) ULC Glare Control 1500 Watt Metal Halide (ULGC)DesignIlluminance (maintained)infield/outfi

Page 6

Typical LayoutsPole LocationSofttball lighting is divided into the infield and outfield portions of the field. The infield lighting is supplied bylumi

Page 7

Sports LightingSoftballStandard 1500 Watt Metal Halide (PSFA) ULC Glare Control 1500 Watt Metal Halide (ULGC)DesignIlluminance (maintained)infield/outfi

Page 8 - Mobile Cart

Typical LayoutsPole LocationThe number of poles and their locations are determined by the pole setback from the edge of the field. Toprevent glare for

Page 9

Standard 1500 Watt Metal Halide (PSFA) ULC Glare Control 1500 Watt Metal Halide (ULGC)DesignIlluminance(maintained)FieldDimensionsPolesLayout #Fixture

Page 10 - Sports Lighting

Typical LayoutsLuminaire SelectionNo individual floodlight should produce more than the average design illumination level at any point on thefield. Fl

Page 11

Standard 1500 Watt Metal Halide (PSFA) ULC Glare Control 1500 Watt Metal Halide (ULGC)Design Illuminance(maintained)PolesLayout #Fixture QuantitiesLay

Page 12 - Baseball

Parking Lot Lighting pg. 23Entrance & Roadway Lighting pg. 23Wall & Flood Lightingpg.25Tennis Court Lighting pg. 17-18Soccer & Football Li

Page 13

TYPICAL LAYOUTSPole LocationPole locations are selected to produce uniform lighting on the entire play area while accenting the court area.Three poles

Page 14 - Softball

Sports LightingTennisStandard 1000 Watt Metal Halide (PSFA)DesignIlluminance(maintained)Court Information Poles Fixture QuantitiesWidth Length Layout

Page 15

APPLICATIONSFor 15 to 35 ft. (5 to 11 meter) applications requiring high efficiencyand the need for low glareVB5 VersabeamTMLuminaireHigh Bay or Low B

Page 16 - Luminaire Mounting Height

Sports LightingGymnasium Lighting• Innovative products• Highest quality• Numerous choices• Fixtures for a variety of mounting heightsand applications•

Page 17

Design DataDesign data on page 26 is for a 44,000-lumen 400-watt metal halide pulse start lampin a medium dirt environment after 8,000hours of operati

Page 18 - Football

Sports LightingGymnasium LightingCourt LayoutsRoom reflectances: 50/30/20Dotted circles indicate luminaire positions. Layouts given are suggestions on

Page 19

Area Lighting PlacementGeneral Rules of ThumbAreas lighted from central locations can be moreeconomical but periphery locations are alsodesirable to p

Page 20 - TYPICAL LAYOUTS

Walkway LightingArea LightingWalkways & TrailsStreetDreams®AveryTMAPPLICATIONS• Parking areas, roadways and walkways• Access roads, paths• IESNA c

Page 21

CriterionTMWall LuminaireAPPLICATIONS• Building perimeter security, high-activityentrances• Full cut-off to limit light trespass• Wall mounted luminai

Page 22 - Indoor Sports Lighting

Skygard®201SA Unit PackAPPLICATIONS• For outdoor work yards, equipment buildings,suburban developments, rural homes and yardswhere reduced glare and f

Page 23

Baseball and Softball Lightingpgs. 9-12Gymnasium Lightingpg. 19-22Stadium Lighting *Playgrounds & SkateparkLighting *Track Lighting *Path & Wa

Page 24 - Gymnasium Lighting

Parks:Sports LightingThe following represents a partial lisiting of completed sports projects by GE LightingSystems.30 877-798-6702 • www.GELightingSy

Page 25

Memorial Park, Las VegasMiami ArenaMile High Stadium – Denver Broncos(original and new stadium)Molson Centre, MontrealOakland Coliseum – Oakland Raide

Page 26 - Parking Area Lighting

GE Lighting Systems andTotal Lighting Control Product Offering:USA3010 Spartanburg Hwy.East Flat Rock, NC 28726T + 1.828.693.2000F + 1.828.693.2570Vis

Page 27 - Walkway Lighting

Select OpticalIts easy to determine the best solution to your sports lighting needs. Follow these steps to choose whichelements of the Lighting System

Page 28 - Flood & Wall Lighting

www.GELightingSystems.com • 877-798-6702 5Sports LightingSystem SelectionWiring BoxIntegralBallast System(shown with platform)RemoteBallast BoxDirect

Page 29 - Wall Lighting Glare Control

POWR • SPOT®III Luminaire• UL 1598 listed for Wet Locations.• CSA/cUL certified. IP-55 construction.• Die cast aluminum ballast housing.• Enclosed, ga

Page 30

www.GELightingSystems.com • 877-798-6702 7Sports LightingSystem SelectionLight TrespassSports lighting at Parks and Recreationalfacilities should be d

Page 31

The System That Lowers Fixtures to YouSportStar is a mobile sports lighting service system. By“mobile”, we mean the fixtures can be lowered from theto

Page 32 - GE Lighting Systems and

Outdoor sports lighting is a specialized form offloodlighting. Pole locations, mounting heights, andluminaire aiming are selected to light the ball in