GE PSFA Fiche technique Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
Warm Up & Restrike Time
HID lamps require 3-7 minutes to warm up and will
not restrike immediately if there is momentary power
interruption. Some form of instant-on lighting,
usually one or two incandescent luminaries per pole,
is recommended to provide lighting during the 1-15
minute restrike time. In addition, the incandescent
(quartz) type fixtures should be used for emergency
lighting of the fields when required. HID fixtures with
optional “hot lamp restrike” capability are available
but this option is “hot restrike only and does not provide
“instant light” when the fixtures are cold started.
Stroboscopic Effect
The light output of HID lamps tends to follow the
60-cycle current waveform. This will cause a moving
object to appear to flicker or jump from position to
position. This is most pronounced when the object
is small and traveling over 50 feet per second. If the
object is moving toward the player or the player is
following the motion of the object, strobe will be
less noticeable. This annoyance can be minimized
by using three-phase power with HID lamps. Metal
Halide lamps, do not produce as much stroboscopic
effect and can be used successfully on single-phase
power.
Design Criteria
The design information in this guide is based on
published lamp and luminaire performance that are
inherent in their design. Normal manufacturing
tolerances cause changes in a lamp’s electrical
characteristics and lumen output. Light changes in
reflector finish and lamp position can alter the
photometric distribution of the luminaire. Changes in
the ballast and line voltage will also alter the output
of the lamp. As a result of these variations average
illumination levels can be expected to vary within
10% of the design value. Individual point by
point foot-candle values can vary more than this,
especially when only a few luminaires are involved,
resulting in little overlap between luminaires.
Aiming Diagrams
Aiming diagrams for each sport should be requested
at the time the order is placed. The instructions for
10 877-798-6702 www.GELightingSystems.com
Sports Lighting