Typical Layouts
Pole Location
Softtball lighting is divided into the infield and outfield portions of the field. The infield lighting is supplied by
luminaires on the A poles. The B & C poles light the outfield. “E” poles are optional pole locations when outfield
“D” poles are not possible. Locating poles as shown on the diagram insures the ball will be lighted on both sides
anywhere on the field. The illumination extends from the ground to the highest point reached by a hit ball. This
insures that the ball will never pass between a player and the floodlights.
Luminaire Mounting Height
The mounting height is selected to keep normal play below the line of sight of the luminaires. This also depresses
the floodlight aiming to avoid unnecessary glare. The larger the field the higher the mounting height must be to
keep the same average aiming angles.
Aiming Diagrams
Aiming diagrams are available for each recommended system in format on. If there is a major change in lighting
requirements or pole locations, it is best to leave the beam type and quantity to the Application Engineering
department at the factory.