Design Data
Design data on page 26 is for a 44,000-
lumen 400-watt metal halide pulse start lamp
in a medium dirt environment after 8,000
hours of operation (40% of the 20,000-hour
rated life) at an average of 10 hours per start.
The ballast is NuVation
TM
Electronic HID.
In gymnasium applications, GE recommends
flexible mounting on a hook and loop to
minimize the risk of damage if a luminaire is
struck by a moving ball. Safety chains
should be used for each ballast housing and
for each optical assembly.
Gymnasium Lighting with
Versabeam Luminaires
The enclosed and gasketed GE Versabeam
Luminaire projects light efficiently to both
horizontal and vertical planes, with more
downward efficiency than other luminaires
intended for low to medium mounting
heights. This attractive luminaire offers low
glare, but with enough uplight for acceptable
ceiling brightness. The rugged acrylic
refractor is impact resistant. The luminaire
may be remotely ballasted.
Application
Horizontal:
Uniformity:
Foot-candles (fc)/Maintained
Maximum/Minimum
Basketball:
High School 75 2.1
Elementary 50 3.0
Club 50 3.0
Recreational 30 3.0
Gymnastics 30 2.5
Volleyball 30 3.5
Basketball court: 94’ by 50’
Lamp: 400-watt metal halide pulse start
NuVation
TM
Ballast
Mounting height: 22’
Illuminance levels: average maintained foot-candles
LLF = 0.79: LLD = 0.85 and LDD = 0.93
Uniformity: maximum/minimum (max/min)
Fixture Spacing Criterion: 1.7
Illumination Engineering of North America (IESNA)
Illumination Recommendations
24 877-798-6702 www.GELightingSystems.com
Sports LightingSports Lighting