BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all NEC and local codes.
• Use only UL approved wire for input/output connections.
Minimum size 14 AWG.
• Type IC, inherently protected.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant d’’inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d’alimentation électrique.
RISQUES D’INCENDIE
• Respectez tous les codes NEC et codes locaux.
• N’utilisez que des ls approuvés par UL pour les entrées/sorties de
connexion. Taille minimum 14 AWG.
• Type IC, protection inhérente.
Provided in the Package
• Luminaire
Pre-installed knockout closure (2 Pieces) for 1/2” trade size conduit knockouts
• Universal mounting brackets (4 pieces)
• M3x12mm screws for mounting bracket installation (8 pieces)
• M3 wingnut (8 pieces)
• Ceiling grid screw for grid and bracket xing (4 pieces)
• M4x16mm screw for bracket to bracket xing (2 pieces)
• M4 nut for bracket to bracket xing (2 pieces)
• Primary diffuser
• Optional low glare diffuser with protective foil
• Joiner pins (2 pieces)
Tools and Components Required
• For end cover install: Philips headed screwdriver
• Rigid (RMC) or exible (FMC) metal conduit for supply connection
• UL/cUL approved twist-on-wire connectors, min. 14 AWG
• UL/cUL approved conduit ttings for 1/2” conduit trade size (2 pieces)
• For bracket to bracket xing: 7mm wrench or socket
• Use BL4x Series (SKU: 85598) or BL6x Series (SKU: 63263) End Cover to
terminate row
Important
• 120V 60Hz - maximum 69 feet of luminaires can be connected on a
single through wiring run.
• 220V 60Hz - maximum 126 feet of luminaires can be connected on a
single through wiring run.
• 277V 60Hz - maximum 159 feet of luminaires can be connected on a
single through wiring run.
• Please see technical data sheet for electrical properties to ensure
safe installation.
• Under any circumstance, maximum driver current through connected
xtures shall not exceed 7A.
Save These Instructions
Use only in the manner intended by the manufacturer. If you
have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
• The LED driver must be supplied with 120-277 VAC,
60 Hz and connected to an individual properly
grounded branch circuit. Use min. 600V 75°C supply
conductor.
Grounding Instructions
• The grounding and bonding of the overall system
shall be done in accordance with National Electric
Code (NEC) Article 600 and local codes.
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - LED Luminaires

GELightingimagination at work(BL Series - Continuous Run Option)LuminationTM LED LuminairesInstallation GuideBEFORE YOU BEGINRead these instructions c

Page 2 - Wiring Diagrams

Wiring DiagramsFollow diagram A for 1-10V, diagram B for DALI or diagram C for Lutron dimming. At output side of LED driver, make appropriate connecti

Page 3

35Connect to the AC line with twist-on wire connectors: Black to live, White to neutral, Green/yellow to ground, Gray to 1-10V dimming, Violet to comm

Page 4 - Luminaire Installation

1For the luminaires that will be in the middle of the run, insert two pins into one end only. Slide pins into the bottom screw grooves, leaving approx

Page 5 - Diffuser Installation

6879Plug together wires between luminaires.Join mounting brackets together with M4 hex head screw and nut. Also tighten wingnuts. Make sure that there

Page 6 - 1-888-69-43-533

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interf

Commentaires sur ces manuels

Pas de commentaire