1
For the luminaires that will be in the middle of the run,
insert two pins into one end only. Slide pins into the
bottom screw grooves, leaving approximately 20-22mm
exposed.
2
Pre-install the two M3x12 mm screws with the wingnuts
into bracket. The screws should be in the same hole type.
3 4
5
Insert four mounting brackets (two per side) into
grooves on both sides of luminiare. Position brackets
approximately 2-3mm from ends. Do not tighten
wingnuts yet.
Fasten one end cover (BL4X - SKU 85598, BL6X - SKU 63263)
on the rst and last luminaires only with four M3 screws.
Always use a star washer under one of the top screws to
ensure ground continuity. Use retained end covers, star
washers and screws.
Note: The luminaires between the rst and last luminaire
do not require end covers.
Place luminaires into ceiling grid.
Do not
tighten yet
Must use star
washer on top hole
20-22mm
End cover
First luminaire Middle luminaire(s) Last luminaire
End coverNo end covers
Pins
Ceiling grid
Pins
Joiner Pin