GE BL Series Guide d'installation Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 6
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class
[A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe [ A ] est conforme á la NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
GE2023-6159
SAP: 1343133
IND071-052214
GE Lighting • 1-888-MY-GE-LED • gelighting.com
1-888-69-43-533
GE Lighting is a subsidiary of the General Electric Company. Lumination is a trademark of GE Lighting. The GE brand and logo are trademarks of the General Electric Company.
© 2014 GE Lighting. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
Troubleshooting
Symptom Solution
Luminaire does not light • Check input voltage and check power supply input/output connections.
• Check circuit breaker.
Luminaire is dim • Dimming wire connection shall be checked and if connection is not proper, reconnect it.
If wire is harmed, replace it with an intact one. Also check that dimming wires are not in
short circuit.
Luminaire is blinking • Ensure power supply temperature does not exceed its maximum rating.
• Refer to the tc point located on power supply.
Luminaire does not dim • Check dimming wire connection.
Luminaires will not turn on • Check that the color of the supply side wires match the color of the wires they are
connected to.
• Check that the LED driver connector is fully engaged to the LED light engine connector.
• Check that the LED light engines are connected at the junction between the two
luminaires.
Luminaire on through
wiring will not turn on
• Check that the through wiring connector from the previous xture in the linear row is fully
engaged to the malfunctioning luminaire.
2 3
Place diffuser to be trimmed on a clean surface. Apply
masking tape over cutting area. Score plastic with utility
knife to about 50% of plastic thickness.
Position score over table edge and carefully snap off
end. Remove tape, le edge, and clean. Install diffuser as
instructed in Step 1.