1 INSTALL DOWNDRAFT VENT
A
Two stabilizing brackets must be installed on
each side of the downdraft vent.
For right-side or straight-down blower
discharge, fasten the stabilizing brackets at
locations A, B, D and E.
For left-side blower discharge, fasten the
stabilizing brackets at locations B, C, D and E.
B
Place the downdraft vent into the countertop
FXWRXWVRWKDWWKHEDFNÀDQJHRIWKHYHQWLV
sitting on top of the countertop.
Note: The downdraft vent may need to be
WXUQHGDWDQDQJOHWR¿WLQWRWKHFRXQWHUWRS
cutout.
C
Secure the screws for the stabilizing brackets to
the cabinet back and side walls.
D
Check that the downdraft vent is vertically level.
Operate the vent 3 to 5 times to ensure proper
installation.
Installation Instructions
2 INSTALL DUCTWORK
• The downdraft blower system is designed for use
ZLWK[GXFWZRUN,WFDQEHWUDQVLWLRQHGWR
6" round.
'XFWZRUN0867EHYHQWHGWRWKHRXWVLGH³QHYHU
in a crawl space, attic or other enclosed space.
• 6" PVC duct should be used when installing under a
concrete slab.
NOTE: Local building code must be followed for
installation in specifying approved type and schedule
of PVC duct used.
'212786(ÀH[LEOHSODVWLFGXFWLQJ
• Always use appropriate roof or wall cap with damper.
/DXQGU\W\SHZDOOFDSVVKRXOGQHYHU
be used.
• Use the straightest duct run possible.
• For satisfactory performance, the duct run should
not exceed 100 ft. or its equivalent length when
EHQGVRUYDULRXV¿WWLQJVDUHXVHG5HIHUWRWKHWDEOH
of equivalent lengths to calculate your installation.
• Install ductwork so the piece of duct nearest the
downdraft unit slots INTO the next piece of the duct.
6HFXUHWKHMRLQWVZLWKVHOIWDSSLQJVFUHZVDQGDSSO\
duct tape around the joints to ensure an airtight seal.
Duct Tape
Over Seam and Screw
Screw
Air
Flow
Bracket
Cabinet Back
Wall
Downdraft Vent
Location A
TOP VIEW
A
C
E
Place Cooktop into the countertop cutout. There
should be a 1/8” minimum gap between the
front of the vent trim and the rear of the cooktop.
It may be necessary to readjust the cooktop and
repeat steps C and D.
A
D
C
B
E
4 to 5”
4 to 5”
Top
Brackets
Bottom
Brackets
Level
Level