Installation Instructions
3 INSTALL REMOTE SWITCH
Connect Wire Lead to Control Box
• Connect the mating wire ends.
3ODFHWKHDGKHVLYHZLUHFODPSVSURYLGHGQHDU
the mating connector.
.HHSDSSUR[LPDWHO\ORQJZLUHDQGDWWDFK
the wire to the clamp with a wire tie. This will act
as a strain relief.
 'ULOODGLDKROHLQWRWKHGHVLUHGORFDWLRQ8VH
the mounting bracket as a template to locate the
hole accurately. Check for interference between
WKHVZLWFKFRYHUDGMDFHQWREMHFWVDQGFRRNWRS
vent overlaps.
If switch is mounted into a tile surface, drill the
hole between tiles. Use locally approved caulking
to cover any gaps.
If the remote switch is not installed on the coun
tertop, ensure that it is installed in a location that
meets local codes and is easily accessible.
Connect Remote Switch to Remote Harness
7KUHDGWKHUHPRWHKDUQHVVWKURXJKWKHGLD
hole and attach the harness connector to the
remote connector.
• Remove the paper backing on the remote switch
foam piece and mount the remote switch on the
countertop such that the switch connectors stay
ORFDWHGLQWKHGLDKROH
6WLFNDGKHVLYHZLUHFODPSQHDUWKHGLDKROH
and attach the loose wire with a wire tie.
WARNING: SHOCK HAZARD
Disconnect electrical power from unit before
beginning switch installation. Failure to do so could
result in personal injury or damage to the electrical
controls.
WARNING: BURN HAZARD
The remote switch must be located so that it can be
operated without reaching over the cooktop. Failure
to do so may result in ignition of clothing which could
cause serious injury or death.
Determine the location for the remote switch.
The remote switch should be located so that the
YHUWLFDOGLVWDQFHIURPWKHÀRRUWRWKHUHPRWH
switch is less than 48" and more than 15".
The remote switch harness is 68" long and should
be installed so that it is not pinched and is away
from moving parts.
Control
Box
'LD+ROH
'LD
Hole
Foam Piece With
Adhesive Mounting
Surface
Foam Piece With Adhesive
Mounting Surface
Remote Switch
Remote
Switch
Strain Relief
$GKHVLYHZLUHFODPS
ZLWKWLH
Remote
Harness
Remote Harness
Mating Connectors
Strain Relief
$GKHVLYHZLUH
FODPSZLWKWLH
Vue de la page 11
1 2 ... 7 8 9 10 11 12 13 14 15 16

Commentaires sur ces manuels

Pas de commentaire