Ge ZONELINE 3200 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes Ge ZONELINE 3200. GE ZONELINE 3200 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
3
Important Safety Information
10
Installation Instructions
Important Electrical Safety
Adjustments and Auxiliary Controls
4
Operating Instructions
The Controls on Your Zoneline
Care of Product
19
Helpful Information
Things That Are Normal
20
If Something Goes Wrong
Before You Call For Service
GE Service Numbers
Warranty
GE Appliances
Zoneline
®
Owner’s Manual
Zoneline Series
Heat Pump Model 3200
Heat/Cool Model 2200
GE Answer Center
®
800.626.2000
49-7359
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Zoneline

3Important Safety Information10Installation InstructionsImportant Electrical SafetyAdjustments and Auxiliary Controls4Operating InstructionsThe Contro

Page 2 - Start Here!

Installation InstructionsRead carefullyIf you have any questions, call the GE Answer Center at 800.626.2000.•Use the correct wall case.This chassis is

Page 3 - SAVE THESE INSTRUCTIONS

Important Electrical Safety—Read CarefullyInstaller: Leave these instructions with the Zoneline.Owner: Keep these instructions for future use.• Follow

Page 4

Installation InstructionsAll wiring, including installation of thereceptacle, must be in accordance with the NECand local codes, ordinances and regula

Page 5 - Energy Tip

These models must be installed using one of thefollowing methods:AElectrical subbase kits are available to providea flexible enclosure for direct con

Page 6 - Other Zoneline features

Installation Instructions6Use the round knockout at the bottom of thejunction box to attach conduit coming fromthe branch circuit. Remove the knockout

Page 7 - Auxiliary Controls

151The RAB71 or RAB77 wall case must beproperly installed per instructions packed with the case.2Remove the corrugated stiffener and theoutdoor protec

Page 8 - Care & Cleaning

16Slide the unit into the wall case and secure withfour screws through the unit flange holes.If an insulated wall case is needed, see Install theWall

Page 9 - Air Filters

Low Voltage Connectors & Auxiliary ControlsNOTE: The owner is responsible for checking all switches and ensuring they are set in the desired setti

Page 10 - Read carefully

Installation InstructionsTo operate the Remote Control/WallThermostat (Class 2) switch #3, you must usean Optional Interface Module kit. See theInstal

Page 11 - Zoneline Components

19Helpful InformationThings That Are NormalNoise Explanation3-MinuteDelayYou may hear a pinging or popping noise caused by water being picked up and

Page 12 - Installation Instructions

Welcome to the GE family. We’reproud of our quality products andwe believe in dependable service.You’ll see it in this easy-to-use manual and you’ll h

Page 13 - 265 Volt Electrical Supply

20The unit is unplugged • Make sure the Zoneline plug ispushed completely into the outlet.The fuse is blown/circuit • Check the house fuse/circuit bre

Page 14

21Problem Possible Causes What to DoBurning Odor at theStart of HeatingOperationDust is on the surface of • This can cause a “burning” odor at the the

Page 16

800.626.2000TDD800-833-4322GE Service NumbersWe’ll be there!Open 24 hours a day,7 days a week.GE Answer Center®800-GE-CARES (800-432-2737)We provide e

Page 17 - Temperature Limiting

Printed in China12-97 CGPub. No. 49-7359Zoneline2200/3200 SeriesWhat Is Not CoveredFULL ONE-YEAR WARRANTYFor one year from date of original pur-chase,

Page 18

• This Zoneline must be properlyinstalled in accordance with theInstallation Instructions before itis used. See pages 10-12.• Repair or replace immedi

Page 19 - Things That Are Normal

4Operating InstructionsThe temp control is used to maintain theroom temperature. The compressor will cycleon and off to keep the room at the same leve

Page 20 - Before You Call For Service

5Energy TipKeep the vent control at CLOSE. The room air will befiltered and circulated.The ventilation control lever is located at thelower left side

Page 21

Operating Instructions Other Zoneline featuresAdditional controls are locatedbehind the room cabinet.To remove: Pull out at the bottom torelease it fr

Page 22

Switch #6 controls the FreezeSentinel. When the switch is DOWN,the Freeze Sentinel automaticallyturns on the resistance heater andfan if the room temp

Page 23 - We’ll be there!

8Operating Instructions Care & CleaningTurn the Zoneline off and discon-nect the power supply.To clean, use water and a milddetergent. Do not use

Page 24 - WARRANTY

Turn the Zoneline off before cleaning.The most important thing you cando to maintain the Zoneline is toclean the filter at least every 30days. Clogged

Commentaires sur ces manuels

Pas de commentaire