Vue de la page 0
1
49-50230-1 03-08 JR
Installation Outdoor Tankless Water Heater
Instructions
Models GN75ENSRSA, GN94ENSRSA, GP94ENSRSA
Questions? Call 888-HOTWTER (888.468.9837) or Visit our website at ge.com
BEFORE BEGINNING INSTALLATION
Read these instructions completely and carefully.
IMPORTANT Save these instructions
for local inspector’s use.
IMPORTANT Observe all governing
codes and ordinances.
Note to Installer Be sure to leave these
instructions with the Consumer.
Note to Consumer Keep these instructions
for future reference.
Proper installation is the responsibility of the
installer.
Product failure due to improper installation
is not covered under the Warranty.
Recognize this symbol as an indication of
Important Safety Information!
WARNING: Read entire manual. Failure to follow all guides and rules could cause personal
injury or property damage.
Check with your state and/or local public works department for plumbing codes. You must follow their
guides as you install the Water Heater.
NOTE: Failure to comply with these installation instructions will void the product warranty, and the
installer will be responsible for any service, repair or damages caused thereby.
SAFETY PRECAUTIONS
WARNING: If the information in these
instructions is not followed exactly, a fire or explosion
may result, causing property damage, personal injury
or death.
FOR YOUR SAFETY!
Do not store or use gasoline or other
flammable vapors or liquids or other
combustible materials in the vicinity of this or
any other appliance. To do so may result in an
explosion or fire.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier,
call the fire department.
Do not return to your home until authorized
by the gas supplier or fire department.
Improper installation, adjustment, alteration,
service or maintenance can cause property
damage, personal injury or death. Refer to
this manual. Installation and service must
be performed by a qualified installer, service
agency or the gas supplier.
Service information and wiring diagram are
located behind front panel.
Service must be performed by a qualified
service agency.
This appliance must be properly grounded and
installed as described in these instructions
.
FOR OUTDOOR APPLICATIONS ONLY
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Instructions

149-50230-1 03-08 JRInstallation Outdoor Tankless Water HeaterInstructionsModels GN75ENSRSA, GN94ENSRSA, GP94ENSRSAQuestions? Call 888-HOTWTER (888.46

Page 2 - SAFETY PRECAUTIONS (cont.)

GAS PIPING (cont.)PIPE SIZING PROCEDUREThe gas supply to the home must be capableof handling the entire gas load of the home,calculated by adding the

Page 3

Installation Instructions11CONNECTING THE WATER HEATERTO THE GAS SUPPLY2Connect the gas supply to the system followingstate and local plumbing codes.

Page 4

12Installation InstructionsWATER PIPINGGENERAL INSTRUCTIONS• The water supply should be shut off whileconnecting the water heater. Make sure thewater

Page 5

13Installation InstructionsCONNECTING THE WATER HEATERTO THE WATER SUPPLYWater connections to the tankless water heatershould follow all state and loc

Page 6

14Installation InstructionsRECOMMENDED PIPING FOR BASIC INSTALLATIONThis is not an engineered drawing; it is intendedonly as a guide and not as a repl

Page 7

FREEZE PROTECTIONFOR EXTERNAL PIPINGIMPORTANT!With electrical power supplied to the waterheater, it will not freeze in environments ascold as -30°F, w

Page 8 - CAUTION: Reinforcement of the

Installation InstructionsELECTRICAL CONNECTIONINFORMATIONWARNING – To reduce the riskof fire, electrical shock and personal injury:The water heater mu

Page 9

CASCADING MULTIPLE WATER HEATERSThe Dual Connect Cable Kit (AGTDC1) is an optionalaccessory that connects 2 water heaters and allowsthem to function a

Page 10 - Installation Instructions

REMOTE CONTROLLER INSTALLATIONLOCATION• The controller shouldbe out of reach of smallchildren.• Avoid locations wherethe controller maybecome hot (nea

Page 11

REMOTE CONTROLLER INSTALLATION (cont.)MOUNTING THE CONTROLLER (cont.)Thread the cable through the access hole at the baseof the unit and connect the w

Page 12

Installation Instructions2SAFETY PRECAUTIONS (cont.)WARNING: Gasoline, as wellas other flammable materials and liquids(adhesives, solvents, paint thin

Page 13

20Installation InstructionsTECHNICAL DATAPRESSURE DROP CURVEOUTLET FLOW DATAGN75GN94/GP94GN75GN94/GP94

Page 14

LADDER DIAGRAM21Installation Instructions

Page 15

22Notes

Page 18 - WARNING: DO NOT ATTEMPT

3Installation InstructionsTOOLS YOU WILL NEED• Pipe Wrenches (2) • Gloves• Adjustable Pliers • Safety Glasses• Screwdrivers (2)• Wire CuttersMATERIALS

Page 19

DIMENSIONSGN75/GN94/GP94ENSRSADIM. DESCRIPTION IN. (MM)A Width 14 (355.6)B Depth 913⁄16 (249.5)C Height – Unit 227⁄8 (582)D Height – with brackets 253

Page 20

5Installation InstructionsFLUE TERMINAL CLEARANCESU.S. INSTALLATIONSCLEARANCES PERREF DESCRIPTION ANSI Z21.10.3A Clearance above grade, veranda, porch

Page 21

6Installation InstructionsFLUE TERMINAL CLEARANCES (ANSI Z21.10.3 • CSA 4.3)FIXEDCLOSEDOPERABLEFIXEDCLOSEDOPERABLEBBBAJBIMCFBBEDLGAHKVENT TERMINAL AIR

Page 22

Installation Instructions7PLANNING FOR PLUMBING(shown with optional pipe cover)The center of the pipes can be placed anywherewithin the shaded area. T

Page 23

Installation Instructions8MOUNTING THE WATER HEATER (cont.)Identify the installation location and confirmthat the installation will meet all requiredc

Page 24

MOUNTING THE WATER HEATER (cont.)ON MASONRY OR CEMENT WALL: Mount4 wall anchors (not supplied) suitable tocarry 200 lbs minimum tensile load each.Leve