Voltage, settable in steps of 1 kV 5 - 300 kV (depending on the tube head)
Current, settable in steps of 0.1 mA 0.5 - 10 mA (depending on the tube head)
Exposure time in 1 sec steps or as min/sec value 1 to 5994 sec (optional display 99 min / 99 sec)
Pre programmable exposure programs max. 250
Memory Size for event and warm-up records 256 for each
Display transflective, backlit, graphic-display, 320 x 240 pixel
Supported languages 19
Character Sets 4, European (ISO), Japanese, Chinese, Cyrillic
Exposure Calculator on-board, Fe, Ti, Al pre programmed / 3 materials free programmable
Warm-up fully automatic, based on real time clock
Tube head identification automatic
Parameter monitoring continuous, on-line display of temperatures, pressure and line-voltage
Serial interface RS 232 1
Safety interlocks 2 (primary also available)
Emergency-Stop button 1
Three-position key switch OFF, STANDBY, ON
Power supply requirements *) 1 PE N, 160 V - 253 V AC, max. 13 A single phase with grounded neutral,
1 PE N, 80 V - 127 V AC, max. 20 A, 50/60 Hz
Dimensions see drawing
Weight 8.6 kg (19 lbs)
Protection class IP65
Operating Temperature -20°C to +70°C
Storage Temperature -30°C to +80°C
Technical Data
*) Operation with reduced output is possible at mains voltages below 205 V and 108 V respectively.
Standard Delivery Scope of complete X-ray unit
ERESCO MF4 tube head (see sep. product information)
Digital Control “ERESCO MF4 Control”
Canvas bag
Connecting cable for ERESCO MF4, various length up to 60 m (193 ft)
Power connecting cable 230 V or 115 V, 10 m (32 ft) long
Set of accessories containing: spare fuses, spare bulbs and Allen key
Options
External fail-safe ashing warning lamp
Aluminium transport box
MF4 Administrator Kit (CD-ROM and Interface Cable)
Connecting cable for door contacts
Extension cable ERESCO MF4,
20 m / 10 m (64 ft / 32 ft)
Portable electric power generator for ERESCO MF
Exposure calculator (PC based)
Primary interlock kit
Adapter cable for ERESCO MF3 radiation unit,
20 m / 0.5 m (64 ft / 1.6 ft) long
Exemplary screenshots of user Interface