Vue de la page 1
monogram.com
93
Built-in all-refrigerators
and all-freezers
Fully integrated
refrigerators /wine reserve
Free-standing
refrigerators
Built-in bottom-freezer
refrigerators
Built-in side-by-side
refrigerators
Advance planning for 36" built-in bottom-freezer refrigerators
The installation space

Product dimensions
429Dia9
*84" From
Floor to
Top Frame
35"
Case Width
*83-1/2"
at
Rear
Case Depth:
25-3/8" Framed Models
25-3/4" Stainless Steel Models
Depth Including Handles:
26-7/8" Framed Models
27-3/4" Stainless Steel Models
28-11/16" Professional Models
36"
Frame to Frame Width

refrigerator can be

cutout that is 83-1/2" min.
to 84-1/2" max. height.

the front is 1/2" higher
and will overlap upper
cabinetry or soffit.
Use leveling legs and
wheels for a maximum

The cutout depth must be 24"


The cutout depth beneath a soffit


bottom of the soffit.
Electrical

An individual properly grounded branch circuit or circuit

3-prong electrical receptacle recessed into the back wall.

Note:
Water line

cold water line can enter the opening through the floor or

kit or 1/4" O.D. copper
tubing between the cold water line and the water connection

easily accessible shut-off valve in the water line is required.
6"
Wall View
Electrical
Area
84-1/2" max
83-1/2" min
Finished
Opening
75" From
Floor to
Bottom
of Electrical Area
10"
24" Cutout Depth
35-1/2"
Finished Width
2-5/16"
5"
10"
10"
3-1/2" 3-1/2"
5"
3-1/2"
Water Supply
605Dia20
25"
Min. to
Wall
130°
130° Door Swing
23-7/8"
Behind
Frame
36-3/4"
605Dia21
90°
90° Door Swing
4" Min. to Wall
5" Min. for Professional Models
Door swing clearances








removal is restricted.





ZUG2, ZUGSS2 and ZUGPP2 unified grille panel kit


71-1/2" wide.
Note: Additional cutout width may be required when side
panels are used. Add side panel thickness to the finished
cutout to calculate rough-in width.

be located as shown.

recommended for each product.

below the bottom storage drawer on the right side.
Vue de la page 1
1 2 3 4 5 6 7

Commentaires sur ces manuels

Pas de commentaire