RG4 LED Level Crossing Signal Modules
8 inch (200mm)
Dimensions in inches. (mm) indicates metric equivalent
Mechanical Outline
8.4"
(210)
3.8"
(95)
2.4"
(60)
6.0"
(153)
7.6"
(194)
Min.
Peak Value
650 Cd
50%
325 Cd
10%
65 Cd
27.5 22.5 17.5 12.5 7.5 2.5 0 2.5 7.5 12.5 17.5 22.5 27.5
27.5
22.5
17.5
12.5
7.5
2.5
0
2.5
7.5
12.5
17.5
22.5
27.5
Visible Distance 7500 ft (2200m)
RG4 RTFB 43B
Operating Specifications
Parameter Rating
Operating Temperature -40 to +70°C (-40 to +158°F)
Operating Voltage Range
8V to 20V DC
8V to 16V AC (50-60Hz)
Voltage Turn-Off (VTO) 4V
Power Surge 45Vrms for 80ms.
Maximum Current Draw 1.2A
Design Compliance
Parameter Compliance
Environmental Limits AREMA Part 11.5.1 -Class B
Electronic Noise FCC Title 47 Sub.B Sec. 15 Class A
Transient Immunity AREMA Part 11.3.3
Product Information
Dominant Nominal Peak Beam Angles Field Angles
Model Wavelength Power Intensity (50% of peak (10% of peak
Number (nm) (W) (cd) intensity) intensity)
RG4-RTFB-43B 630 13 650 18°H x –11°V 38°H x –16°V
All values are design or typical values when measured under laboratory conditions at T=25˚C.
Photometric Characteristics
Distributed by:
GELightingSolutions•1-888-MY-GE-LED•www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand and logo are trademarks of the General Electric Company.
© 2011 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.