PT920SM
GE Profile
30" Built-In Single Convection Wall Oven
Note: 36ribbon cooktops are approved for use
over GE 30” single wall ovens only. 30” ribbon
cooktops are approved for use over GE 30” and
GE 27” single wall ovens. Refer to cooktop and
wall oven installation information packed with
products for current dimensional data.
Note: CleanDesign or Sealed Burner Gas
This installation is to achieve minimum gap
between bottom of countertop and control
panel. For this installation, the bottom trim will
not be flush with a typical 4” toe kick
Note: Cabinets installed adjacent to wall ovens
must have an adhesion spec of at least a 194°F
temperature rating.
Installation Information: Before installing,
consult installation instructions packed with
product for current dimensional data.
Power cord
for cooktop
Junction box
for oven
Junction box in
adjacent cabinet
for cooktop
hook-up
2 (two) 90°elbows &
sufficient pipe to
connect in adjacent
cabinet
Right cabinet side
3/4" Support
Shut-off
valve
Pressure
regulator
1/2" Black
iron pipe
Union
Conduit
(72" long)
30" built-in
oven
3-1/2" MIN.
Free space
4" To 4-1/2"
3-1/4
22
Side View
With 36" Gas Cooktop
With 30" CleanDesign or Sealed Burner Gas Cooktop
5-9/16"
Reference dim.
for MAX. support
height with typical
36" countertop
height
36" Typical
Countertop height
Power cord
Reference
5-9/16
30-7/16
Free space
1-1/2" MIN.
1-1/2" Typical countertop
Side View
22
27-5/16" MAX.
Cutout height
27-1/4" MIN.
Junction box(s) for
oven & radiant
cooktop 22" from
floor
Add suitable
filler to match
adjacent cabinets
when needed
to maintain toe
kick alignment
30" Oven W/ Rad. Cktp.
5
24
25
Gas or electric cooktops may be installed
over this oven. See cooktop installation
instructions for cutout size. See label on
top of oven for approved cooktop models.
Gas (including the pressure regulator) and
electrical connections for gas cooktop must
be located in an adjacent accessible location.
For a 30" gas cooktop, the connections are
more conveniently made to the right.
120 Volt
Outlet
Gas
connection
Junction box
location
240/208V
36'' MIN.
4'' To 4-1/2 '' Toe kick allowable
Match toe kick height
front and two sides
22'' MIN. above
support platform
Top and/or side
fillers may be
necessary if unit
is positioned
between
existing cabinets
28-1/2'' MIN.
28-5/8'' MAX.
3/4'' Support
platform required
23-1/2" MIN.
Cutout depth
Allow 11/16''
overlap over side
edges of cutout
1-1/2"
Countertop
27-1/4'' MIN.
27-5/16'' MAX.
Cutout height
Specification Created 1/07
220239
Optional Undercounter Dimensions and Installation Information
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.