GE JV356 30 Manuel d'utilisateur Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
2
Venting
This hood must be vented vertically through
upper cabinets or horizontally through an outside
wall. Ductwork is not included.
Improper duct sizing or restrictive roof caps
reduce air moving capacity and will not provide
enough ventilation for an indoor electric grill.
Indoor electric grills produce more smoke than
normal cooking and require at least 410 CFM to
provide adequate ventilation.
Follow the guidelines for proper duct sizing in the
ducting charts. NOTE: The venting system must
exhaust to the outside.
Cabinet Height
For most efficient operation, the top of the hood should
be approximately 66(167.6 cm) from the floor.
Non-Venting
Follow the instructions under “Vented Installation” for
wiring and mounting. Omit the ductwork preparation.
Install WB13X5008–Charcoal filter pads replaceable.)
Tools Required:
• Drill; 1
1
4
wood bit. Pliers.
• Flat blade screwdriver.• Pencil, ruler and level.
• Saber saw or keyhole saw.
• Caulking, metal snips, duct tape, ducts (with
elbow and transition, if necessary) and wall cap
or roof caps, as required.
INSTALLATION INSTRUCTIONS
Installing the Range Hood
Determine which direction the vent will be
installed (top or rear).
1. Remove filters and motor/light cover (3 screws).
2. Remove the blower motor by removing the
“packing screw” and the clip on the retainer bar.
Discard the clip and screw.
Unplug the motor from the junction box.
Snap the blower retainer
bar toward the rear of
the hood to release the
blower. Remove the
blower.
3. Remove the junction
box cover.
Remove the selected wiring knockout and duct
knockout from the top or rear of the hood. Use a
flat blade screwdriver to cut the tabs.
IMPORTANT: OBSERVE ALL GOVERNING
CODES AND ORDINANCES.
SAVE THESE INSTRUCTIONS FOR THE
LOCAL ELECTRICAL INSPECTOR’S USE.
WARNING: Disconnect power before servicing or cleaning the unit.
Care of Filter Care of Exterior Surfaces Charcoal Filter Pads
(not included)
For greatest efficiency the aluminum
filter should be cleaned periodically.
To remove the filter, pull the tab to
the side and then down. Soak it in hot
water and detergent. Rinse and dry
thoroughly before replacing.
Use a mild detergent to clean the hood.
DO NOT use abrasive cleansers.
Lights
This hood has two lights. Do not use
bulbs larger than 75 watts. There are
two light levels. To change light
bulbs, first remove the filters. It is not
necessary to remove the blower cover.
This filter should be inspected
periodically and, when it becomes
saturated, it should be replaced. There
are no effective means of reactivating
this filter. Order WB13X5008.
Top Vent
Knockout
Snap
lock blower
retainer bar
Vent-less operation discharge vent
Vue de la page 1