Ilnstallation
nstruct,ons
RangeHood
Models JV535 JV635
JV536JV636
JV565 JV665
JV566JV666
Questions?visitour_vVebsiteat: www.geappliances.com orCarlGEAnswer Center at 800.626.2000 [
BEFORE YOU BEGIN
Read these instructions completely mad carefully.
IMPORTANT - S.,ethese
instHwtions fi)r local inspector's use.
IMPORTANT - Obse,,e.ll
governing codes and ordinances.
Note to Installer - Be sure to leave these
instHwtions with the Consmner.
Note to Consumer - Kee I) these instructions
ti)r fllture reference.
SMll level - Installation of this appliance requires
basic mechanical and electrical skills.
Completion time - 1-3 horn's
Proper installation is the responsibility of the
installeL
" Product thihu'e due to improper installation is not
covered trader the Warranty.
" Use only with approved cord kit, JXHC1.
FOR YOUR SAFETY:
WARNING - Before begiIlIliIlg the
installation, switch power off at service panel and lock
the service disconnecting means to prevent power
from being switched on acddentally. When the service
disconnecting means cannot be locked, secm'elv
tasten a prominent warning device, such as a tag,
to the setMce panel.
DUCTWORK REQUIREMENTS
NOTE: Read the ductwork sections tufty if you do not
have existing ductwork. If you have existing ductwork,
skip to the "Damage" section mad proceed.
The venting system must exhaust to the outside.
This hood can be xented verticall) through upper
cabinets or hofizoi_tallv throuoh an outside wall.
Ductwork is not included.
Exhaust connection:
The hood exhaust has been designed to mate with
standard 3¼" x 10" rectangular ducting or 7" diameter
rotmd ducting.
If a 6" rotmd duct is required, a rectangula>to-round
transition adaptor must be used*. Do not use less thm_
a 6" dimneter duct.
Maximum duct length:
For satistactory air movement, the total duct length
of a 3V(' x 10" rectangular; 6" or 7" diameter rotmd
duct should not exceed 65 equivalent feet.
NOTE: It's important that ducting be installed using
the most direct route and with as few elbows as possible.
This ensm'es clear venting of exhaust and helps prevent
blockages. Also, mane sure dampers swing freely and
nothing is blocking the ducts.
Elbows, transitions, wall and roofcaps, etc.,
present additional resistance to airflow and are
equivalent to a section of straight duct longer than their
actual l)hysical size. When calculating the total duct
length, add the equi\:dent lengths of all transitions and
adaptors plus the length of all straight duct sections. The
charts on the fl)llowing pages show you how to calculam
total equivalent ductwork length using the approximate
tibet of equiwdent length of some t'},pical ducts.
* IMPORTANT: If a rectangula>t(>
round transition adaptor is used, the
bottom corners of the damper will
have to be cut to fit, using the fin
snips, in order to allow fl'ee
movement of the dampeL
Equiwdent lengths of duct pieces
are based on actual tests and reflect
requirements fl)r good venting
perfl)rmance with anv hood.
6