Dryer Exhausting Information Metal Duct Only
For complete information, see installation instructions packed with your dryer.
Ducting Materials: For best performance, this dryer should be vented with 4” diameter
allrigidmetalexhaustduct.Ifrigidmetalductcannotbeused,thenUL-listedflexible
metal(semi-rigid)ductingcanbeused(KitWX08X10077).Inspecialinstallations,itmay
benecessarytoconnectthedryertothehouseventusingaflexiblemetal(foil-type)duct.
AUL-listedflexiblemetal(foil-type)ductmaybeusedONLYininstallationswhererigid
metalorflexiblemetal(semi-rigid)ductingcannotbeusedANDwherea4”diametercan
be maintained throughout the entire length of the transition duct. Please see installation
instructionpackedwithyourdryerforcompleteinstructionswhenusingflexiblemetal(foil
type) ducting.
Exhaust Length Calculation:
1. Determinethenumberof90°turnsneededforyourinstallation.Ifyouexhausttothe
side or bottom of dryer, add one turn.
2. Themaximumlengthof4’rigid(aluminumorgalvanized)ductwhichcanbetoleratedis
shown in the table.
A turn of 4 or less may be ignored. Two 45° turns within the duct length should be
treated as a 90° elbow.
A turn over 45° should be treated as a 9elbow.
Dryers mustbeexhaustedtotheoutside.
Caution: Forpersonalsafetydonotterminateexhaustintoachimney,underanyenclosed
house floor (crawl space), or into an attic, since the accumulated lint could create a fire
hazardormoisturecouldcausedamage.Neverterminatetheexhaustintoacommonduct
orplenumwithakitchenexhaust,sincethecombinationoflintandgreasecouldcreatea
fire hazard.
Exhaustductsshouldbeterminatedinadamperedwallcaptopreventbackdrafts,bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any other
obstruction with the opening pointed down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
DCVH680GJ
GE
®
7.0 Cu. Ft. Super Capacity Frontload Gas Dryer
Best performance
Domestic
dryer models
Maximum length of 4"
dia. rigid metal duct
Number
of
90°
turns
Exhaust hood type
A
4"
opening
B
2-1/2"
opening
7.0, 6.0 and 5.8 cu. ft.
capacity models
all gas dryers
0
1
2
3
90 ft.
60 ft.
45 ft.
35 ft.
60 ft.
45 ft.
35 ft.
25 ft.
A
4
B
2-1/ 2
A