6 ERESCO MF4
* Operation with reduced output is possible at main voltages below 205 V and 108 V respectively
** Available for selected models
Technical Specifications
ERESCO MF4 – Serie
ERESCO-Typ 200 MF4-R 280 MF4-R 300 MF4-R
Description A real time imaging
device, with small
focal spot (EN12543),
for applications
requiring geometric
enlargement
A real time imaging
device, with small
focal spot (EN12543),
for applications
requiring geometric
enlargement
A real time imaging
device, with small
focal spot (EN12543),
for applications
requiring geometric
enlargement or fast
exposure time
Emergent Beam Direct Emission Direct Emission Direct Emission
Penetration of Steel in 10 min - - 65 mm (2.55”)
High Voltage Range 10 - 200 kV 10 - 280 kV 5 - 300 kV
Tube Current Range 0.5 – 10 mA 0.5 - 4.5 mA 0.5 - 6 mA
Tube Current at U max 3.0 mA / 200 kV 1.2 mA /280 kV 3.0 mA / 300 kV
Continous Rating 600 W 340 W 900 W
Nominal Focus Spot Value
1.0 mm (EN 12 543)
0.5 (IEC 336)
0.5 mm (EN 12543) 1 mm ( EN 12543)
Anode Material Tungsten (W) Tungsten (W) Tungsten (W)
Target Angle 20° 15° 15°
Emergent Beam Range Elliptical, 40° x 60° Elliptical, 30° x 60° Elliptical, 30° x 60°
Inherent Filtration 0.8 ± 0.1 mm, Be 0.8 mm ± 0.1 mm Be 0.8 mm ± 0.1 mm, Be
Cooling Air-cooled
Duty Cycle (1 h operation time) 100%
Current and Voltage Stability ± 1 %
Power Supply Requirements 160 V - 253 V AC, 80 V - 127 V AC, 50/60 Hz *
Weight of Tube Head 26.8 kg (59.1 lbs) 40 kg (88,2 lbs) 40 kg (88,2 lbs)
Certifications CE Conformity, NFC 74100 **, BfS Certification (PTB Approval) **
Vue de la page 5