Installation Instructions
GT1
TM
Pedestrian 12” Incandescent Look Signal Modules
Overlay – Countdown – Full Hand – Full Person
Installation Steps:
1. Verify input voltage is within specified range on the back of the LED signal module before
installation. Failure to do so will cause lamp to fail.
2. Open front cover of (customer supplied) traffic signal housing.
3. Remove cable tie-wraps (qty. 2) from wire bundle.
4. Connect the wires to the appropriate terminal block within customer supplied signal housing.
Orange wire ( + for Hand )
Blue wire ( + for Person )
White wire ( for the neutral )
5. Close front cover of (customer supplied) traffic signal housing ensuring that the module gasket is
tight within the housing.
12 x 12 inch Overlay 12 x 12 inch Countdown
12 x 12 inch Full Hand/Person
Voltage Rating
Conversion to Half Cycle (if required)
1. Remove plastic end-cap.
2. Remove jumper wire from the unit
3. Put end-ca
p
back on
Risk of Electric Shock
Install unit in enclosure tested to
be suitable for wet locations only.
Prepare Electrical Wiring
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Electrical Requirements
Do not use in wet locations
Follow all National Electric Codes
(NEC) and local codes.
GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. GT1 is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General
Electric Company. © 2010 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under
laboratory conditions.
TRAF046-R120110
Vue de la page 0
1

Résumé du contenu

Page 1 - Installation Instructions

Installation Instructions GT1TM Pedestrian 12” Incandescent Look Signal Modules Overlay – Countdown – Full Hand – Full Person Installation St

Commentaires sur ces manuels

Pas de commentaire