11
Adjust the Switch
The downdraft is factory-adjusted for proper
operation. However, shipping and handling may
affect the positions of the activating switch.
To adjust position of activating switch:
1. If the downdraft is plugged into the electrical
outlet, unplug it.
2. Lift the air vent straight up and cock it slightly
so it remains in the UP position.
3. Remove the switch cover from the right end
of the air vent.
4. Loosen the 2 screws holding the switch
bracket in place. Position the switch bracket so
that the activating switch just comes in contact
with the underside of the switch membrane.
Tighten the screws.
5. Replace the switch cover, gently lower the
air vent into the chimney, and plug in the power
cord. Re-connect the electrical power and check
operation.
WARNING: To avoid possible electrical
shock, personal injury or death—
disconnect electrical power.
Install the Cooktop
1. Align the cooktop with the downdraft and
fasten cooktop in place.
NOTE: Accurate alignment of cooktop and
downdraft is necessary to ensure that there is
not interference when air vent is raised and
lowered. There should be a gap of 1/32–1/16
between the back of the cooktop and the front of
the downdraft cover.
Switch
bracket
Switch
cover
Screws
Switch membrane