Built-In “J” Series Cool Only Specifications
GE
®
Built-In “J” Series Heat/Cool and Heat Pumps Specifications
Models
AJCQ08ACB AJCQ10ACB AJCQ10DCB AJCQ12DCB AJCS06LCB AJCS08ACB AJCS10ACB AJCS09DCB AJCS10DCB AJCS12DCB AJCH08ACB AJCH10ACB AJCH10DCB AJCH12DCB
ENERGY STAR
®
••••••••••
Voltage 115 115 230/208 230/208 115 115 115 230/208 230/208 230/208 115 115 230/208 230/208
Cooling Capacity
BTUH-AHAM 8000 9900 9900/9700 11600/11400 6000 8000 9900 8900/8700 9900/9700 11600/11400 8000 9900 9900/9700 11600/11400
Amps-AHAM 7.9 9.7 4.9/5.3 5.8/6.3 5.7 7.9 9.7 4.2/4.6 4.9/5.3 5.8/6.3 7.9 9.7 4.9/5.3 5.8/6.3
Watts Input 840 1040 1040/1020 1220/1200
600 840 1040 935/915 1040/1020 1220/1200 840 1040 1040/1020 1220/1200
EER 9.5 9.5 9.5/9.5 9.5/9.5 10.0 9.5 9.5 9.5/9.5 9.5/9.5 9.5/9.5 9.5 9.5 9.5/9.5 9.5/9.5
Dehumidification (Pts./Hr.) 2.1 2.9 2.9 3.4 1.4 2.1 2.9 2.5 2.9 3.4 2.1 2.9 2.9 3.4
Features
Line Cord Plug Parallel Parallel Tandem Tandem Parallel Parallel Parallel Tandem Tandem Tandem Parallel Parallel Tandem Tandem
Recommended Circuit Protection
(Time Delay) 15 Amps 15 Amps 15 Amps 15 Amps 15 Amps 15 Amps 15 Amps 15 Amps 15 Amps 15 Amps 15 Amps 15 Amps 15 Amps 15 Amps
Fan Speeds 3 3 3 3 2 2 2 2 2 2 2 2 2 2
Fan Only Setting 3 3 3 3 2 2 2 2 2 2 2 2 2 2
Air Flow (CFM) Roomside Hi/Low 240/212 282/254 282/254 304/279 212/184 240/212 282/254 282/254 282/254 304/279 240/212 282/254 282/254 304/279
Air Exchange Exhaust
••••••••••
Fan Cycle Switch
••••••••••
Rotary Compressor
••••••••••
Slide-Out Chassis
••••••••••
Installation In Wall In Wall In Wall In Wall In Wall In Wall In Wall In Wall In Wall In Wall In Wall In Wall In Wall In Wall
Wall Case Required
RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48
Approximate Net Weight (lbs.) 68 77 77 79 63 68 77 69 77 79 69 78 78 80
Approximate Shipping Wt. (lbs.) 77 86 86 88 72 77 86 79 86 88 78 87 87 89
Electronic Units Mechanical Units High-Mount Units
GE
®
All cooling with electric heat models and heat pumps are corrosion treated. Specifications and design subject to change without notice. *These units are not intended to be the primary source of heat.
Model AJES06LSB* AJES08ASB* AJES10DSB AJES09DCB AJES10DCB AJES12DCB AJEH12DCB AJHS08ASB* AJHS08DCB AJHS10DCB
Voltage 115 115 230/208 230/208 230/208 230/208 230/208 115 230/208 230/208
Cooling Capacity
BTUH-AHAM 6000 8000 9900/9700 8900/8700 9900/9700 11600/11400 11600/11400 8000 8000/7800 9900/9700
Amps-AHAM 5.7 7.9 4.9/5.3 4.2/4.6 4.9/5.3 5.8/6.3 5.8/6.3 7.9 4.0/4.3 4.9/5.3
Watts Input 600 840 1040/1020 935/915 1040/1020 1220/1200 1220/1200 840 840/820 1040/1020
EER 10.0 9.5 9.5/9.5 9.5/9.5 9.5/9.5 9.5/9.5 9.5/9.5 9.5 9.5/9.5 9.5/9.5
Dehumidification (Pts./Hr.) 1.4 2.1 2.9 2.5 2.9 3.4 3.4 2.1 2.1 2.9
Reverse Cycle Heating
BTU-AHAM 7700 7700/7500 9700/9500
C.O.P. at 47°F. 3.0 3.0/3.0 3.0/3.0
Amps-AHAM 6.8 3.4/3.7 4.3/4.7
Watts Input 750 750/730 950/930
Electric Resistance Heating
BTUH 4100 4100 11600/9500 11600/9500 11600/9500 11600/9500 11600/9500 4100 11600/9500 11600/9500
Amps 12.0 12.0 16.0 16.0 16.0 16.0 16.0 12.0 16.0 16.0
Watts Input @ 230V 1380 1380 3670/3010 3670/3010 3670/3010 3680/3020 3680/3020 1380 3660/3000 3680/3020
Features
Line Cord Plug Parallel Parallel Perp. Perp. Perp. Perp. Perp. Parallel Perp. Perp.
Recommended Circuit Protection
(Time Delay) 15 Amps 15 Amps 20 Amps 20 Amps 20 Amps 20 Amps 20 Amps 15 Amps 20 Amps 20 Amps
Fan Cycle Switch
••• ••••
Fan Speeds, Heating/Cooling 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2 2/2
Fan Only Setting 2 2 2 2 2 2 2 2 2 2
Air Flow (CFM) Roomside Hi/Low 212/184 240/212 282/254 282/254 282/254 304/279 304/279 237/212
237/212
304/279
Air Exchange Exhaust
••• ••••
Rotary Compressor
••• ••••
Slide-Out Chassis
••• ••••
Installation Window/Wall Window/Wall Window/Wall In Wall In Wall In Wall In Wall Window/Wall In Wall In Wall
Wall Case Required Included Included Included RAB46/47/48 RAB46/47/48 RAB46/47/48 RAB46/47/48 Included RAB46/47/48 RAB46/47/48
Window Installation Kit Std. Mount Std. Mount Std. Mount Optional Optional Optional Optional Std. Mount Optional Optional
Approximate Net Weight (Lbs.) 82 87 96 71 78 80 81 TBD TBD TBD
Approximate Shipping Wt. (Lbs.) 97 102 111 80 88 90 90 TBD TBD TBD
Heat/Cool Units High-Mount Heat Pumps
GE
®
Air Conditioner Tips
Air Flow – Keep air filters clean. Do not block air flow areas.
Roomside View – J-models feature concealed power cord storage, this eliminates
excessive cord exposure when receptacle is located close to unit.
Accessories
Other accessories are available, they include: Fedders and Whirlpool sleeve adapters.
Drain kits and Chassis adapters for old Hotpoint cases.