Installation of the range.
Electrical Power Supply Requirements
Recommended Electrical Outlet Locations
Recommended acceptable electrical
outlet area. Orient the electrical
receptacle so the length is parallel
to the floor.
Provide Proper Electrical Supply
These ranges must be supplied with 208/240 volt,
60 Hz., and connected to an individual, properly
grounded circuit protected by a circuit breaker
or time-delay fuse (40 amp). The receptacle must
be NEMA 14-50R to accept the 4-prong plug
supplied with the range.
If the electrical service provided does not meet
the above specifications, it is recommended that
a licensed electrician install an approved outlet.
Locate the electric supply as illustrated.
7-1/2
8
4
30
3
Product is shipped with 4-prong plug.
Recommended outlet is a NEMA 14-50R
receptacle.
2-1/4
Wall Mounted
NOTE: Make electrical connections
on the right side of the cutout opening.