Active Vent
The active vent consists of the fan, motor, housing,
and vent louver motor.
The active vent helps to reduce the noise level and
heat loss when in the closed position. The control
module supplies +/- 12 VDC to the vent louver
motor. The control module reverses polarity to drive
the motor in a clockwise or counterclockwise (open
or closed) direction.
The vent closes 8 seconds after the main pump
is switched on during the fi rst fi ll cycle and opens
during the drying cycle (heated and non-heated).
The vent is open during cooldown periods or when
the unit is not in use.
If the vent is closed and the door is opened during
the wash cycle, the vent will open. When the door
is closed again, the vent will remain open for 8
seconds, then close again to fi nish the cycle.
It is normal for water vapor to come through the
active vent during the dry cycle. The active vent can
be opened and closed using the
Service Mode.
The vent louver is held in place by a single screw.
Remove the motor from the mount by rotating the
motor 90° in the mount and sliding it out between
the tabs.
Note: The gear in the mount is held in place with the
motor.
Vent Motor Strip Circuit
J5-2
RED BLK
M J5-1
Note: Foam with double-sided tape holds the
conduit in place. The foam tears easily if pulled
during removal of the housing.
Six Phillips head screws hold the fan and motor to
the vent housing.
Fan Motor Strip Circuit
65 W
FAN
DK. BLUE/RED
M
WHITE
J2-3
Note: This also applies to the Rinse Only cycle.
Since heated dry is not an option with Rinse Only,
the fan will run for approximately 4 hours before
turning off.
To access the vent fan and motor, remove the door
panel (see Door Panel).
The vent fan and motor housing are held in place
by:
4 long, silver Phillips head screws.
2 short, brass Phillips head screws (see photo).
Fan (PDW9700 AND PDW9900 Series)
During natural dry, the fan runs for approximately
4 hours after the last drain cycle is completed
(clean light on). During heated dry, the fan runs for
approximately 2 hours after the last drain cycle is
completed. If the door is opened, the fan stops and
the control stops counting down. When the door is
relatched, the fan will start again and the control will
continue to count down. Touching any key will turn
off the fan.