165D6290G029
THIS DISHWASHER IS PROGRAMMED WITH A SERVICE MODE TO AID THE TECHNICIAN IN TROUBLESHOOTING THE DISHWASHER.
EACH COMPONENT MAY BE CYCLED TO DETECT IF IT IS FUNCTIONING CORRECTLY. COMPONENTS ARE CYCLED BY PRESSING
KEYPADS TO THE LEFT OF THE START/RESET KEYPAD. USE THE MATRIX BELOW TO DETERMINE HOW TO CYCLE EACH COMPONENT.
MODELS WITHOUT A TURBIDITY SENSOR
Service Mode Test Matrix*
Keypad Description Time in Seconds**
10 Activates Main Pump 120
Activates Auxiliary Pump 60
9
Activates Drain Solenoid 6
8 Activates Detergent Module 30
7 Activates Water Valve 60
6 Activates Heating Element 120
START/RESET Used to EXIT Service Mode
1098765 3421
NOTE: INDICATES KEYPAD USED ONLY ON SOME MODELS. WHILE THIS KEYPAD MAY
NOT BE VISIBLE, THE INDICATED SPACE SHOULD ALWAYS BE USED AS A KEYPAD.
TO ENTER SERVICE MODE :
PRESS KEYPAD #9 AND KEYPAD #1 SIMULTANEOUSLY FOR
5 SECONDS.
TO EXIT SERVICE MODE :
PRESS THE START/RESET KEYPAD AT ANYTIME TO EXIT.