Ge ZSC1202NSS Manuel d'utilisateur Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
monogram.com
23
Above-the-cooktop
Advantium
Speedcook ovens
Microwave ovensMicrowave ovensWarming drawers
Advantium
®
Speedcook
wall ovens
This Monogram built-in oven can be installed directly into a
wall, a 30"-wide oven cabinet or below a countertop and
specified cooktops. It can also be installed alone, with a single
oven or with a warming drawer. Create a complete cooking
center by installing the Advantium with both.
These ovens may be installed side by side or stacked one over
the other. See installation instructions for details.
Electrical requirements
Product rating is 120V, 60Hz, 15-amp circuit and draws 1.8 kilowatts.
It must be connected to a supply circuit of the proper voltage and
frequency and protected by a time-delay fuse or circuit breaker.
An Advantium 120 oven installed in combination with any other
appliance must be supplied with separate electrical connections.
Cutout and product dimensions
Advantium 120 oven installed alone
Order a 30"-wide single oven cabinet or cut the opening
in a wall to the dimensions shown.
Advance planning for 30" wall ovens with Advantium
120
Speedcook technology
Advantium 120 oven installed above a Monogram
single wall oven
The Advantium 120 oven and single oven combination
must be supplied with separate electrical connections.
Note: Additional
clearance between
cutouts may be
required. Check to
be sure the oven
supports above the
warming drawer
location do not
obstruct the required
interior depth and
height. See each
specific product’s
installation instructions
for details.
30"
23-1/2"
17-1/2"
Construct Solid
Bottom Min. 3/8"
Plywood
Supported by
2 x 4 or 2 x 2
Runners all
Four Sides
2" Min.
Per Oven
Requirement
2" Min.
Per warming drawer requirement
25-1/4"
Note: The oven is only approved
to be installed under the specific
models labeled on the unit.
Advantium 120 oven installed above a Monogram
single wall oven and a warming drawer
The Advantium 120 oven and single oven combination
must be supplied with separate electrical connections.
The warming drawer must be supplied with a separate
120V, 60Hz, properly grounded receptacle.
Advantium 120 oven installed below a countertop
and/or cooktop.
Monogram cooktops ZGU36K, ZEU36R, ZEU30R and ZEU36K
may be installed above the Advantium 120 oven.
Advantium 120 oven installed above a Monogram
warming drawer
An anti-tip block must be installed at the rear of the
warming drawer opening. Again, see installation
instructions for complete details.
The warming drawer must be supplied with a separate
120V, 60Hz, properly grounded receptacle.
30"
23-1/2"
Construct Solid
Bottom Min. 3/8"
Plywood
Supported by
2 x 4 or 2 x 2
Runners all
Four Sides
2" Min.
Per Warming
Drawer
Requirement
25-1/4"
17-1/2"
30"
23-1/2"
Construct Solid
Bottom Min. 3/8"
Plywood
Supported by
2 x 4 or 2 x 2
Runners, all
Four Sides
2" Min.
Per Oven
Requirement
17-1/2"
25-1/4"
The middle rail
separating the two
openings may need to
be larger than the
2" min. shown.
30"
23-1/2"
Construct Base
Min. 3/8"
Plywood
Supported by
2 x 4 or 2 x 2
Runners all
Four Sides
17-1/2"
530Dia3
25-1/4"
19"
29-3/4"
21-1/2"
Recessed
Depth
Note: Additional
clearance between
cutouts may be
required