GE ZV830 Manuel d'utilisateur Page 9

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 60
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 8
9
INSTALL FRAMING
FOR HOOD SUPPORT
IMPORTANTFraming must be capable
of supporting 100 lbs.
If drywall is present, mark the screw hole locations for
the top mounting brackets. Remove the template.
Cut away enough drywall to expose 2 vertical studs
at the bracket location indicated on the template.
Install a horizontal support at least 1
x 6
between two wall studs at the mounting screw
location. The horizontal support must be flush with
the room side of the studs. Use cleats behind both
sides of the support to secure to wall studs.
IMPORTANT: Reinstall drywall for an even mounting
surface.
1
Centerline of
Installation
Space
8" Min. Opening for Ductwork
View From Rear
Cleats
1" x 6" Min.
Mounting
Support
Installation Instructions
Centerline of
installation
space
View from rear
cleats
1” x 6” min.
mounting
support
DUCTWORK, WIRING LOCATIONS
Determine the exact location of the vent hood.
Locate the template packed with the literature.
Measure 36 from the floor to the top of the cooking
surface. Add hood installation height determined on
page 7. Mark that location.
Use a level to draw a straight pencil line on the wall.
Tape the template in position along the penciled
line. CHECK TO BE SURE THE TEMPLATE IS LEVEL.
Ceiling ducting:
If ductwork will vent straight up to the ceiling:
Use a level to draw a line straight up, from
the centerline on the template to the ceiling.
Measure 5-1/2
from the back wall to the centerline
of an 8-1/2
hole on the ceiling.
NOTE: If drywall is not present, add drywall thickness
to the 5-1/2
dimension.
Wall Ducting:
If ductwork will vent to the rear:
Use a level to draw a line straight up from
the centerline on the template.
Measure at least 27-3/4
above the pencil line
that indicates the bottom installation height, to the
centerline of an 8-1/2
dia. duct hole. (Hole may
be elongated for duct elbow.)
HOUSE WIRING LOCATION:
The junction box is located on the top left side
of the hood.
Wiring should enter the back wall at least 18
above
the bottom of the hood, and within 5-1/2
of the left
side of the centerline.
INSTALLATION—VENTED TO THE OUTSIDE
8-1/2” min. opening for ductwork
Installation Height
Align Bottom Edge With
Pencil Line Indicating
Bottom of Hood
REAR WALL
MOUNTING TEMPLATE
49-80514 10/07 JR
Printed in Mexico
15-7/16
15-7/16
10-1/16
C
L
1-1/4
1-1/4
9-7/16
9-7/16
TOP
MOUNTING
HOLE
DRILL 1/8
PILOT HOLE
TOP
MOUNTING
HOLE
DRILL 1/8
PILOT HOLE
BOTTOM
MOUNTING
HOLE
BOTTOM
MOUNTING
HOLE
NOTE:To p
mounting
screws MUST
engage wood
support.
NOTE: Top
mounting
screws MUST
engage wood
support.
Installation Height
Align Bottom Edge With
Pencil Line Indicating
Bottom of Hood
Ceiling
House Wiring
Location
C
L
5-1/2”
18”
Min.
Wall vent
27-3/4” min.
above
installation
height
5-1/2” centerline to wall
FOR CEILING VENT DUCTING
8-1/2” dia. hole
Vue de la page 8