GE GDT226SSLSS Manuel d'installation Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
4
Installation Preparation
Cabinet Preparation & Wire Routing
The wiring may enter the opening from either side, rear
or the floor within the shaded area illustrated above
in figure and as defined in PREPARE DISHWASHER
ENCLOSURE section.
Cut a 1-1/2" maximum diameter hole to admit the
electrical cable. Edges of hole should be smooth and
rounded. Permanent wiring connections may pass
through the same hole as the drain hose and hot water
line, if convenient. If cabinet wall is metal, the hole
edge must be covered with a bushing.
NOTE:
Power cords with plug must pass through a
separate hole in the cabinet.
Electrical Connection to Dishwasher
Electrical connection is on the right front of dishwasher.
For permanent connections the cable must be routed
as shown in figure. Cable must extend a minimum of
24" from the rear wall.
For power cord connections, install a 3-prong grounding
type receptacle in the sink cabinet rear wall, 6" min. or
18" maximum from the opening, 6" to 18" above the floor.
Use only WX09X70910 (5’ 4” long) or WX09X70911
(7’ 9” long) Dishwasher Power Cord Kit. Do not use an
extension cord or adapter plug with this appliance.
PREPARE ELECTRICAL WIRING
Electrical Requirements
• This appliance must be supplied with 120V, 60 Hz.,
and connected to an individual properly grounded
branch circuit, protected by a 15- or 20-ampere circuit
breaker or time-delay fuse.
Wiring must be 2 wire with ground and rated for 167°F
(75°C).
If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
Grounding Instructions–Permanent Connection
This appliance must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
be connected to the equipment-grounding terminal or
lead on the appliance.
Grounding Instructions–Power Cord Models
This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk
of electric shock by providing a path of least resistance
for electric current. This appliance is equipped with a
cord having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into an
appropriate outlet that is installed and grounded in
accordance with all local codes and ordinances.
The improper connection of the equipment grounding
conductor can result in a risk of electric shock. Check with
a
qualified electrician or service representative if you are in
doubt that the appliance is properly grounded. Do not modify
the plug provided with the appliance; if it will not fit the outlet,
have a proper outlet installed by a qualified technician.
WARNING
Remove all power leading to the appliance from the
circuit breaker or fuse box before beginning installation.
Failure to do so can result in a risk of electrical shock.
WARNING
1-1/2” Dia.
Hole (Max.)
3”
from
Cabinet
24”
from Wall
Ground
Black
White
Metal Cabinet
Wall
Cord Protector
(Obtain locally
as needed)
Hole Diameter
1-1/2” Maximum
Vue de la page 3
1 2 3 4 5 6 7 8 9 ... 35 36

Commentaires sur ces manuels

Pas de commentaire