Ge ZDP364NDPSS Manuel d'utilisateur Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 68
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
Installation Preparation
4-WIRE POWER CORD INSTALLATION
NOTE: A 4-wire cord is connected to the range
at the factory. Use the following steps to change
an existing installation from a 3-wire cord back
to a 4-wire cord.
WARNING
The neutral wire of the supply circuit must be
connected to the neutral terminal located in the
lower center of the terminal block. The power
leads must be connected to the lower left and
the lower right terminals of the terminal block.
The 4th grounding lead must be connected to
the frame of the range with the ground plate
and the ground screw.
Remove the 3 lower terminal screws from
the terminal block. Remove the ground screw
and ground plate and retain them.
Remove the ground strap. DO NOT DISCARD
THE GROUND STRAP OR ANY SCREWS.
Insert the one ground screw into the power cord
ground wire terminal ring, through the ground
plate and into the frame of the range.
Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral)
is connected to the center lower position
of the terminal block. Tighten screws securely
into the terminal block.
Before
After
Terminal
Block
Terminal
Block
Neutral
Terminal
Neutral Terminal
Ground Strap
Ground
Plate
(grounding
to range)
Ground
Screw
Ground Strap
or
3-WIRE POWER CORD INSTALLATION
NOTE: A 4-wire cord is connected to the range
at the factory. Use the following steps to change
the range to a 3-wire cord.
WARNING
The neutral or ground wire of the power cord
must be connected to the neutral terminal located
in the center of the terminal block. The power leads
must be connected to the lower left and the lower
right terminals of the terminal block.
Remove the ground strap (located at the right
side of the terminal block) and connect between
the center lower portion of the terminal block
to the frame of the range.
Remove the 3 lower terminal screws from
the terminal block. Insert the 3 terminal screws
through each power cord terminal ring and
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral)
is connected to the center lower position
of the terminal block. Tighten screws securely
into the terminal block.
DO NOT remove the ground strap connection.
Ground
Strap
Terminal
Block
(appearance
may vary)
Neutral
Terminal
Power Cord
Ground
Plate
10