GE PT878GC Manuel d'utilisateur Page 100

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 308
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 99
Programming Site Data 4-39
April 2004
Entering the Analog Output
The Analog Output option enables you to enter information to set
up output parameters. To enter the option, scroll to the Analog
Output entry on the Program Menu and press
[ENTER]. The
screen appears similar to Figure 4-18 below. To step through each
parameter, press the [T] key. Refer to Figure A-6 on page A-6 of
Appendix A, Menu Maps.
Figure 4-18: The Analog Output Window
1. The first prompt enables you to select a range to send a current
signal to a recording device.
a. Press
[ENTER] to open the drop-down menu.
b. Scroll to the desired output from three choices: Off,
0-20 mA, and 4-20 mA.
c. Press
[ENTER] to confirm your selection.
Note: If you select “Off,” you cannot access any other
parameters in this option.
Analog Output
Cancell OK
Function
Data Source
Zero
On Error
0-20 mA
Velocity
Span
Hold Last Value
0
m/s
25.5
Vue de la page 99
1 2 ... 95 96 97 98 99 100 101 102 103 104 105 ... 307 308

Commentaires sur ces manuels

Pas de commentaire