GE PT878GC Manuel d'utilisateur Page 76

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 308
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 75
Programming Site Data 4-15
April 2004
Entering the Signal Path Parameters
To enter the Path option, scroll to the Path entry on the Program
Menu and press
[ENTER]. (From the Lining window, you can
scroll back up to the Lining tab and press the [X] arrow key to
reach the Path window, and press
[ENTER].) The screen appears
similar to Figure 4-6 below. To step through each parameter,
press the [T] key. Refer to Figure A-3 on page A-3 of Appendix
A, Menu Maps.
Figure 4-6: The Signal Path Window
Note: The Path Length and Axial Length parameters are not
available for clamp-on transducers.
Transducer
Pipe Lining
Path
Transducer/Pipe
Cancell
OK
Fluid
Path Length
Axial Length
Traverses
1
Spacing
248.92
203.2
90
mm
mm
mm
Vue de la page 75