WARNING RISK OF FIRE
• To reduce the risk of severe injury or death, follow all installation instructions.
• Clothes dryer installation must be performed by a qualied installer.
• Install the clothes dryer according to these instructions and in accordance with local
codes. In the absence of local codes, installation must comply with National Fuel Gas
Code, ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code,
CSA B149.1.
California Safe Drinking Water and Toxic Enforcement Act.
This act requires the governor of California to publish a list of substances known to the
state to cause cancer, birth defects or other reproductive harm and requires businesses
to warn customers of potential exposure to such substances. Gas appliances can
cause minor exposure to four of these substances, namely benzene, carbon monoxide,
formaldehyde and soot, caused primarily by the incomplete combustion of natural gas
or LP fuels. Properly adjusted dryers will minimize incomplete combustion. Exposure
to these substances can be minimized further by properly venting the dryer to the
outdoors.
• This dryer must be exhausted to the outdoors.
• Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors.
DO NOT install a clothes dryer with exible plastic ducting materials. If exible metal
(semi-rigid or foil-type) duct is installed, it must be UL listed and installed in accordance
with the instructions found in “Connecting The Dryer To House Vent” on page 6 of this
manual. Flexible venting materials are known to collapse, be easily crushed, and trap
lint. These conditions will obstruct dryer airow and increase the risk of re.
• Do not install or store this appliance in any location where it could be exposed to water
and or weather.
• Dryers installed in residential garages must be elevated 18” (46 cm) above the oor.
• Save these instructions. (Installers: Be sure to leave these instructions with the
customer).
In the state of Massachusetts, installation must be performed by a qualiedor
licensed contractor, plumber, or gastter qualied or licensed by the state.
Installation
Instructions
Gas Dryer
06
Questions on Installation? Call: 1-800-GECARES (US)
or Visit our Web site at: www.GEAppliances.com (US)
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
IMPORTANT- Save these instructions for
local inspector’s use.
IMPORTANT- Observe all governing codes
and ordinances.
Note to Installer - Be sure to leave these
instructions with the customer.
Note to Customer - Keep these instructions
with your Use and Care Book for future
reference.
• Before the old dryer is removed from service or
discarded, remove the dryer door.
• Inspect the dryer exhaust outlet and straighten
the outlet walls if they are bent.
• Service information and the wiring diagram
are located in the control console.
• Do not allow children on or in the appliance.
Close supervision of children is necessary when
the appliance is used near children.
• Install the dryer where the temperature is
above 50°F for satisfactory operation of the
dryer control system.
LEVEL
8" PIPE WRENCH
10" ADJUS TABLE WRENCHES
(x2)
TOOLS YOU
WILL NEED
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
M ATERIALS YOU WILL NEED
EXHAUST HOOD
FLEXIBLE GAS LINE CONNECTOR
SOAP SOLUTION
FOR LEAK DETECTION
PIPE
COMPOUND
DUCT TAPE
GLOVES
SAFETY GLASSES
4" DIAM METAL ELBOW
4" DUCT CLAMPS
OR
4" SPRING CLAMPS
(x2)
(x2)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
234D1113P002 31-16225-1 07/08/10 GE
Step 1 Verify Your Gas Installation (see section 2).
Step 2 Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step 3 Check and Insure the Existing External Exhaust
is Clean (see section 1) and Meets Attached
Installation Specications (see section 6).
Step 4 Remove the Foam Shipping Pads (see section 1).
Step 5 Move the Dryer to the Desired Location.
Step 6 Level Your Dryer (see section 8).
Step 7 Connect the Gas Supply (see section 3) and check
for leaks (see section 4).
Step 8 Connect the External Exhaust (see section 7).
Step 9 Connect the Power Supply (see section 5).
Step 10 Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 11 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed By the Owner.
For Alcove or Closet Installation see section 9.
For Bathroom or Bedroom Installation see section 10.
For Mobile or Manufactured Home see section 11.
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
Vue de la page 0
1 2 3 4 5 6 7 8 9

Résumé du contenu

Page 1 - Gas Dryer

WARNING RISK OF FIRE• To reduce the risk of severe injury or death, follow all installation instructions.• Clothes dryer installation must be performe

Page 2 - Installation Instructions

Installation Instructions2Minimum Clearance Other Than Alcove or Closet InstallationMinimum clearance to combustible surfaces and for air opening are:

Page 3

Installation Instructions33 RECONNECTING GASNote: The connector and ttings are designed for use only on the original installation and are not to be r

Page 4

Installation Instructions45 ELECTRICAL CONNECTION INFORMATIONELECTRICAL REQUIREMENTSThis appliance must be supplied with 120V, 60Hz, and connected to

Page 5

Installation Instructions57 EXHAUST CONNECTIONTHIS DRYER COMES READY FOR REAREXHAUSTING. IF SPACE IS LIMITED, USETHE INSTRUCTIONS IN SECTION 9 TOEXHAU

Page 6

Installation Instructions6CONNECTING THE DRYERTO HOUSE VENTRIGID METAL TRANSITION DUCT• For best drying performance, a rigid metal transition duct is

Page 7

Installation Instructions712DRYER EXHAUST TO RIGHT, LEFTOR BOTTOM CABINET WARNING - BEFORE PERFORMINGTHIS EXHAUST INSTALLATION, BE SURETO DISCONNEC

Page 8

Installation Instructions8PL ATE(KIT WE1M454)13 CHANGING DIRECTION OFDOOR OPENINGADDING ELBOW FOR EXHAUSTTHROUGH BOTTOM OF CABINET• Insert the elbow t

Page 9

Installation Instructions9WATER SUPPLY REQUIREMENTSHot and cold water faucets MUST be installed within 42 in. (107 cm) of your washer’s water inlet. T

Commentaires sur ces manuels

Pas de commentaire