EQUIVALENT
RIGID NUMBER EQUIVALENT
DUCT PIECES LENGTH X USED = LENGTH
Rigid Metal 1 Ft. X ( ) = Ft.
Ducting
(Preferred)
Semi-Rigid 25 Ft. X ( ) = Ft.
Metal Ducting
(inside diameter
does not change)
Flexible Metal 50 Ft. X ( ) = Ft.
Ducting (inside
diameter changes)
Elbows (90°/45°) 10 Ft. X ( ) = Ft.
Turns less 2 Ft. X ( ) = Ft.
Than 4 Ft.
Rigid Metal 1 Ft. X ( ) = Ft.
Ducting
Semi-Rigid 2 Ft. X ( ) = Ft.
Metal Ducting
Flexible Metal Ft.
Ducting Not
Recommended
4 Wall Cap 5 Ft. X ( ) = Ft.
Louvered Wall 10 Ft. X ( ) = Ft.
Cap
2.5 Wall Cap 23 Ft. X ( ) = Ft.
Total Ductwork Length = Ft.
TOTAL MUST BE LESS THAN OR EQUAL TO 90 FT.