Reports
Monitor
Reports
One of the functions available on the Monitor tab is the ability to generate reports. SVi1000
provides the ability to extract information about the SVi1000 operation and dump the
information into a report format. When SVi1000 extracts the information from a device it
requires a template file into which to dump the data. To generate a report with SVi1000 you
must first create a report template file that includes the parameters you would like to
include in the report as well as personalization.
How to Create Reports
There are three basic steps to create reports:
1. Set up the report: Create a report template file.
2. Select the report setup (report template file): Using the Report Setup command from the
Monitor context menu.
3. Generate the report: Using the Report command from the Monitor context menu.
Creating Report Template Files
You can create a custom SVi1000 report by creating a rich text format (RTF) file which is laid
out in the format of the desired report. The default template is located in:
Win7 and 2008 Server: C:\Program Data\Dresser\ValVue\SVi1000\Data.
WinXP and 2003 Server: C:\Documents and Settings\All Users\Application
Data\Dresser\ValVue\SVi1000\Data.
Prior to selecting the set up of the report (Monitor Context menu) you must create the report
template file in an rtf format. The report template includes the operation parameters that
you would like populated in the report.
SVi1000 substitutes the values of SVi1000 parameters into the text file where ever it finds a
parameter name that matches an SVi1000 parameter. For each parameter you would like
included in the report place $$ in front of the parameter name.
For example:
Tag = $$Tag
SVi1000 substitutes the actual tag name from the SVi1000 in place of the $$Tag in the
report.
When creating the report template file, use an application that can save the report template
file to an rtf or text file such as WordPad, Microsoft Word, or Notepad.